Granite Trench Drain Cover Size: Measure the Clear Width, Not the Drawing
A granite trench drain cover is not sized from the channel width on the drawing. Measure the finished clear width, add the bearing on both sides, set thickness from the clear span, and work the length back from what two men can lift at about 70kg. The 30mm slab stocked in Sesame Grey G602 is paving stock; covers need 50–80mm material opened to size, 100 ㎡ minimum, 5 days to ship.
How do you size a granite trench drain cover? Start with the clear width, not the width on the drawing
Three numbers settle a granite trench drain cover: the finished clear width, the bearing on each side, and the weight of one piece. Thickness follows the clear span, not the channel width. The first number is often the one that goes wrong. The width on a drawing is the structural opening; once the walls are built, rendered or a factory-made channel is dropped in, the opening is narrower than drawn. Cut to the drawing and the cover either will not reach the walls or sits on a bearing no wider than a pencil line. So measure the finished clear width: after the rendering is done and the walls are dry, hold the tape against the inner face of both walls, once at each end and once in the middle, and take the largest of the three. Bearing is (cover width − clear width) ÷ 2, so the wider the channel the less bearing the same cover gets; size the cover to the widest reading, which leaves exactly 50mm a side there while the narrower sections simply gain a little more, and use that same figure as the span for thickness. If the readings differ, the walls are not straight or the channel tapers.
How much wider than the channel should the cover be, and how long should the bearing be?
Cover width = clear width + 2 × bearing. A wider bearing is not a more stable cover. 50mm per side is our workshop practice, not a code value: on concrete walls with a flat top and a mortar bed under the cover, 50mm is enough to start; on brick walls, or where the rendered top is visibly uneven, go to 80mm so the cover can bridge it. Beyond that you pay twice. Weight rises with width, so a 600mm cover is half again as heavy as a 400mm one at the same thickness, and two men can no longer lift it. And the longer the bearing, the longer the lever when someone stands on the edge; a cover that is not fully bedded will rock, and a cover that rocks chips its corners. Bed it properly — a full mortar bed, or a continuous rubber strip — never four dabs at the corners. Four dabs leave the middle hanging, and a wheel breaks it there first.
How thick should the cover be? Read the clear span, not the channel width
Thickness follows the clear span. Take the span as the finished clear width and leave the 50mm bearing out; that errs on the safe side, whereas measuring to the bearing centre gives a thinner cover than the calculation justifies. Two relationships are enough to remember, as directions. Under a uniformly distributed load — crowds, stored material, backfill — the mid-span moment rises with the square of the span, so at the same stress the thickness rises in proportion: take the clear width from 300 to 600 and the thickness doubles too. With a single wheel at mid-span, the moment rises only with the span itself, so the thickness rises with the square root: double the width and multiply the thickness by 1.41. Both make the cover thicker as the span grows; only the rate differs, so take the case your drawing specifies and never mix the two. The three rows below are worked examples only; the thickness column follows a design drawing, not a code value and not a stock size. The 60mm in the 400 row is about 10% under the 67mm the proportion gives, so do not copy it to a traffic lane. Change the clear width or the load and the section must be recalculated; an old drawing cannot be copied onto a new channel.
| Clear width (mm) | Cover width (mm, 50mm bearing each side) | Section thickness (mm) | Weight per metre (kg/m) | Max length at 70kg (mm) |
|---|---|---|---|---|
| 300 | 400 | 50 | 54 kg | 1200mm |
| 400 | 500 | 60 | 81 kg | 800mm |
| 500 | 600 | 80 | 130 kg | 500mm |
How long should one cover be? Work backwards from what two men can lift
Length is set by lifting, not by how it looks. Weight = width × thickness × length × 2.7 t/m³, and 2.7 is the density of granite, not a figure from our plant. Take 70kg as the ceiling — two men at roughly 35kg each — and note that this is an assumption; assume four men will lift it on site and put 140 into the same sum. For a cover 500mm wide and 60mm thick: 0.5 × 0.06 × 2.7 = 0.081 t per metre, or 81kg, and 70 ÷ 81 = 0.86, so 800mm per piece. To go longer you either narrow the cover or add hands. Do not go much shorter either: 500–600mm is the usual compromise, and below that the joints multiply, corners double, and chipping in transit and on site rises with them. The 30mm slab we stock in Sesame Grey G602 is paving stock and covers are not cut from it; cover stock at 50–80mm is opened to your sizes, 100 ㎡ minimum, 5 days to ship, and slotted covers are scheduled separately, so give us the length your lifting limit allows instead of asking us to guess it.
How do you set the joints and the inlet slots without weakening the cover?
Take the joint width from the 3–6mm band used for the paving and line the cover joints up with the paving joints either side. How that band is calculated, from thermal movement, tolerance and filler size, is set out in our guide to granite paving joint width, and the cover takes the same band. A cover joint that misses the paving joint is easy to spot. Cut slots in the top face only, the compression side: in bending the top half is in compression and the bottom half in tension, so a slot underneath is a notch cut exactly where tension is highest, and a wheel opens it from the bottom of the slot. Keep a solid length at each end of every slot, starting at one cover thickness — our workshop practice, not a code value — so the section above the wall bearing stays whole; never run a slot out to the end of the cover. A slotted cover has lost section, so add thickness to compensate, as much as you removed. Size the total inlet area at twice the outlet cross-section, one part for flow and one for leaves and grit, again our own rule, for the designer to check against local rainfall intensity.
What numbers go on the order, and what do you check on delivery?
Put seven items on the order, or the plant has to guess: finished clear width; bearing per side; cover width, meaning clear width plus both bearings; thickness, with slot compensation already added; length per piece; joint width; and slot position, width and spacing. Give units with every one. On delivery, four checks take ten minutes. One, tape the cover width from outer edge to outer edge, not along the arris you see from above, which reads small. Two, caliper the thickness at both ends and the middle; readings that do not agree mean uneven thickness, and the cover will rock. Three, set two pieces down together: a joint the same width top and bottom means a straight edge, one that tapers means the cut ran off. Four, look at the slot edges and pull out anything chipped, because a cover that fails tends to fail at the slot. Count the pieces after those four checks. And the line worth keeping: never order the cover at the channel width — the 50mm of bearing is hiding in that difference.